Description
An attacker with network access to an affected product may cause a denial of service condition by breaking the real-time synchronization (IRT) of the affected installation.
| Vendor | Product | Versions |
|---|---|---|
Siemens | Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller | affected All versions < V4.1.1 Patch 05 |
Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 | affected All versions < V4.5.0 Patch 01 |
Siemens | Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P | affected All versions < V4.5.0 |
Siemens | SCALANCE X-200IRT family (incl. SIPLUS NET variants) | affected All versions < V5.2.1 |
Siemens | SIMATIC CP 1604 | affected All versions < V2.8 |
Siemens | SIMATIC CP 1616 | affected All versions < V2.8 |
Siemens | SIMATIC ET 200M (incl. SIPLUS variants) | affected All versions |
Siemens | SIMATIC ET 200MP IM 155-5 PN HF | affected 0 - < V4.2.0 |
Siemens | SIMATIC ET 200MP IM 155-5 PN ST | affected 0 - < V4.1.0 |
Siemens | SIMATIC ET 200pro IM 154-3 PN HF | affected 0 - < * |
Siemens | SIMATIC ET 200pro IM 154-4 PN HF | affected 0 - < * |
Siemens | SIMATIC ET 200pro IM 154-8 PN/DP CPU | affected All versions < V3.2.17 |
Siemens | SIMATIC ET 200pro IM 154-8F PN/DP CPU | affected All versions < V3.2.17 |
Siemens | SIMATIC ET 200pro IM 154-8FX PN/DP CPU | affected All versions < V3.2.17 |
Siemens | SIMATIC ET 200S IM 151-8 PN/DP CPU | affected All versions < V3.2.17 |
Siemens | SIMATIC ET 200S IM 151-8F PN/DP CPU | affected All versions < V3.2.17 |
Siemens | SIMATIC ET 200SP IM 155-6 PN HF | affected 0 - < V4.2.0 |
Siemens | SIMATIC ET 200SP IM 155-6 PN ST | affected 0 - < V4.1.0 |
Siemens | SIMATIC ET 200SP IM 155-6 PN ST BA | affected 0 - < V4.1.0 |
Siemens | SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 4AO U/I 4xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 | affected All versions |
Siemens | SIMATIC ET200ecoPN: IO-Link Master | affected All versions |
Siemens | SIMATIC ET200S (incl. SIPLUS variants) | affected All versions |
Siemens | SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) | affected All versions |
Siemens | SIMATIC S7-300 CPU 314C-2 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-300 CPU 315-2 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-300 CPU 315F-2 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-300 CPU 315T-3 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-300 CPU 317-2 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-300 CPU 317F-2 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-300 CPU 317T-3 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-300 CPU 317TF-3 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-300 CPU 319-3 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-300 CPU 319F-3 PN/DP | affected All versions < V3.2.17 |
Siemens | SIMATIC S7-400 CPU 412-2 PN V7 | affected 0 - < V7.0.3 |
Siemens | SIMATIC S7-400 CPU 414-3 PN/DP V7 | affected 0 - < V7.0.3 |
Siemens | SIMATIC S7-400 CPU 414F-3 PN/DP V7 | affected 0 - < V7.0.3 |
Siemens | SIMATIC S7-400 CPU 416-3 PN/DP V7 | affected 0 - < V7.0.3 |
Siemens | SIMATIC S7-400 CPU 416F-3 PN/DP V7 | affected 0 - < V7.0.3 |
Siemens | SIMATIC S7-400 PN/DP V6 and below CPU family (incl. SIPLUS variants) | affected 0 - < * |
Siemens | SIMATIC WinAC RTX 2010 | affected All versions < V2010 SP3 |
Siemens | SIMATIC WinAC RTX F 2010 | affected All versions < V2010 SP3 |
Siemens | SIMOTION | affected All versions |
Siemens | SINAMICS DCM | affected All versions < V1.5 HF1 |
Siemens | SINAMICS DCP | affected All versions < V1.3 |
Siemens | SINAMICS G110M V4.7 Control Unit | affected All versions < V4.7 SP10 HF5 |
Siemens | SINAMICS G120 V4.7 Control Unit (incl. SIPLUS variants) | affected All versions < V4.7 SP10 HF5 |
Siemens | SINAMICS G130 | affected 0 - < V4.7 HF29 |
Siemens | SINAMICS G150 | affected 0 - < V4.7 HF29 |
Siemens | SINAMICS GH150 V4.7 Control Unit | affected All versions |
Siemens | SINAMICS GL150 V4.7 Control Unit | affected All versions |
Siemens | SINAMICS GM150 V4.7 Control Unit | affected All versions |
Siemens | SINAMICS S110 Control Unit | affected All versions |
Siemens | SINAMICS S120 V4.7 Control Unit and CBE20 (incl. SIPLUS variants) | affected All versions < V4.7 HF34 |
Siemens | SINAMICS S150 | affected 0 - < V4.7 HF29 |
Siemens | SINAMICS SL150 V4.7 Control Unit | affected All versions < V4.7 HF33 |
Siemens | SINAMICS SM120 V4.7 Control Unit | affected All versions |
Siemens | SINUMERIK 828D | affected All versions < V4.8 SP5 |
Siemens | SINUMERIK 840D sl | affected All versions < V4.8 SP5 |
Siemens | SIPLUS ET 200MP IM 155-5 PN HF | affected 0 - < V4.2.0 |
Siemens | SIPLUS ET 200MP IM 155-5 PN HF | affected 0 - < V4.2.0 |
Siemens | SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL | affected 0 - < V4.2.0 |
Siemens | SIPLUS ET 200MP IM 155-5 PN ST | affected 0 - < V4.1.0 |
Siemens | SIPLUS ET 200MP IM 155-5 PN ST TX RAIL | affected 0 - < V4.1.0 |
Siemens | SIPLUS ET 200S IM 151-8 PN/DP CPU | affected All versions < V3.2.17 |
Siemens | SIPLUS ET 200S IM 151-8F PN/DP CPU | affected All versions < V3.2.17 |
Siemens | SIPLUS ET 200SP IM 155-6 PN HF | affected 0 - < V4.2.0 |
Siemens | SIPLUS ET 200SP IM 155-6 PN HF | affected 0 - < V4.2.0 |
Siemens | SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL | affected 0 - < V4.2.0 |
Siemens | SIPLUS ET 200SP IM 155-6 PN ST | affected 0 - < V4.1.0 |
Siemens | SIPLUS ET 200SP IM 155-6 PN ST BA | affected 0 - < V4.1.0 |
Siemens | SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL | affected 0 - < V4.1.0 |
Siemens | SIPLUS ET 200SP IM 155-6 PN ST TX RAIL | affected 0 - < V4.1.0 |
Siemens | SIPLUS S7-300 CPU 314C-2 PN/DP | affected All versions < V3.3.17 |
Siemens | SIPLUS S7-300 CPU 315-2 PN/DP | affected All versions < V3.2.17 |
Siemens | SIPLUS S7-300 CPU 315F-2 PN/DP | affected All versions < V3.2.17 |
Siemens | SIPLUS S7-300 CPU 317-2 PN/DP | affected All versions < V3.2.17 |
Siemens | SIPLUS S7-300 CPU 317F-2 PN/DP | affected All versions < V3.2.17 |
Siemens | SIPLUS S7-400 CPU 414-3 PN/DP V7 | affected 0 - < V7.0.3 |
Siemens | SIPLUS S7-400 CPU 416-3 PN/DP V7 | affected 0 - < V7.0.3 |
Weaknesses (CWE)
CVSS v3.1 Details
CVSS v3.1 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H/E:P/RL:O/RC:C
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability
Security Training
Train your team to recognize and prevent security threats with our comprehensive security awareness program.
Start TrainingVulnerability Scanning
Discover vulnerabilities in your applications and infrastructure before attackers do.
Scan Now