A vulnerability has been identified in SCALANCE S602 (All versions >= V3.0 and < V4.1), SCALANCE S612 (All versions >= V3.0 and < V4.1), SCALANCE S623 (All versions >= V3.0 and < V4.1), SCALANCE S627-2M (All versions >= V3.0 and < V4.1). Specially crafted packets sent to port 443/tcp of affected devices could cause a Denial-of-Service condition of the web server. A cold reboot is required to restore the functionality of the device.

VendorProductVersions

Siemens

SCALANCE S602

affected
All versions >= V3.0 and < V4.1

Siemens

SCALANCE S612

affected
All versions >= V3.0 and < V4.1

Siemens

SCALANCE S623

affected
All versions >= V3.0 and < V4.1

Siemens

SCALANCE S627-2M

affected
All versions >= V3.0 and < V4.1