CVE Database
/

CVE-2020-10264

Back to search

CVE-2020-10264

Published: Apr 6, 2020

Modified: Sep 17, 2024

PUBLISHED

CVSS v3.1

8.8

HIGH

Description

CB3 SW Version 3.3 and upwards, e-series SW Version 5.0 and upwards allow authenticated access to the RTDE (Real-Time Data Exchange) interface on port 30004 which allows setting registers, the speed slider fraction as well as digital and analog Outputs. Additionally unautheticated reading of robot data is also possible

VendorProductVersions

Universal Robots A/S

Universal Robots Robot Controllers CB 3.1

affected
CB3 SW Versions 3.3 up to 3.12.1

Universal Robots A/S

Universal Robots Robot Controllers e-Series

affected
next of SW Versions 5.0 up to 5.7 - < unspecified

Weaknesses (CWE)

CVSS v3.1 Details

CVSS v3.1 Vector

CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Attack Vector

Adjacent

Attack Complexity

Low

Privileges Required

None

User Interaction

None

Scope

Unchanged

Confidentiality

High

Integrity

High

Availability

High