CVE Database
/

CVE-2021-31382

Back to search

CVE-2021-31382

Published: Oct 19, 2021

Modified: Sep 17, 2024

PUBLISHED

CVSS v3.1

6.5

MEDIUM

Description

On PTX1000 System, PTX10002-60C System, after upgrading to an affected release, a Race Condition vulnerability between the chassis daemon (chassisd) and firewall process (dfwd) of Juniper Networks Junos OS, may update the device's interfaces with incorrect firewall filters. This issue only occurs when upgrading the device to an affected version of Junos OS. Interfaces intended to have protections may have no protections assigned to them. Interfaces with one type of protection pattern may have alternate protections assigned to them. Interfaces intended to have no protections may have protections assigned to them. These firewall rule misassignments may allow genuine traffic intended to be stopped at the interface to propagate further, potentially causing disruptions in services by propagating unwanted traffic. An attacker may be able to take advantage of these misassignments. This issue affects Juniper Networks Junos OS on PTX1000 System: 17.2 versions 17.2R1 and later versions prior to 17.3 versions prior to 17.3R3-S12; 17.4 versions prior to 17.4R3-S5; 18.1 versions prior to 18.1R3-S13; 18.2 versions prior to 18.2R3-S8; 18.3 versions prior to 18.3R3-S5; 18.4 versions prior to 18.4R1-S8, 18.4R2-S8, 18.4R3-S8; 19.1 versions prior to 19.1R3-S5; 19.2 versions prior to 19.2R3-S2; 19.3 versions prior to 19.3R2-S6, 19.3R3-S3; 19.4 versions prior to 19.4R2-S4, 19.4R3-S3; 20.1 versions prior to 20.1R3; 20.2 versions prior to 20.2R2-S3, 20.2R3; 20.3 versions prior to 20.3R2-S1, 20.3R3; 20.4 versions prior to 20.4R1-S1, 20.4R2. This issue does not affect Juniper Networks Junos OS prior to version 17.2R1 on PTX1000 System. This issue affects Juniper Networks Junos OS on PTX10002-60C System: 18.2 versions 18.2R1 and later versions prior to 18.4 versions prior to 18.4R3-S9; 19.1 versions later than 19.1R1 prior to 19.4 versions prior to 19.4R2-S5, 19.4R3-S5; 20.1 versions prior to 20.1R3-S1; 20.2 versions prior to 20.2R3-S2; 20.3 versions prior to 20.3R3-S1; 20.4 versions 20.4R1 and later versions prior to 21.1 versions prior to 21.1R2; 21.2 versions 21.2R1 and later versions prior to 21.3 versions prior to 21.3R2. This issue does not affect Juniper Networks Junos OS prior to version 18.2R1 on PTX10002-60C System. This issue impacts all filter families (inet, inet6, etc.) and all loopback filters. It does not rely upon the location where a filter is set, impacting both logical and physical interfaces.

VendorProductVersions

Juniper Networks

Junos OS

unaffected
unspecified - < 17.2R1
affected
17.2R1 - < 17.2*
affected
17.3 - < 17.3R3-S12
affected
17.4 - < 17.4R3-S5
affected
18.1 - < 18.1R3-S13

+11 more versions

Juniper Networks

Junos OS

affected
18.4 - < 18.4R3-S9
affected
19.1R1 - < 19.1*
affected
19.4 - < 19.4R2-S5, 19.4R3-S5
affected
20.1 - < 20.1R3-S1
affected
20.2 - < 20.2R3-S2

+6 more versions

Weaknesses (CWE)

CVSS v3.1 Details

CVSS v3.1 Vector

CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:L/I:L/A:L

Attack Vector

Network

Attack Complexity

High

Privileges Required

None

User Interaction

None

Scope

Changed

Confidentiality

Low

Integrity

Low

Availability

Low

References

Security Training

Train your team to recognize and prevent security threats with our comprehensive security awareness program.

Start Training

Vulnerability Scanning

Discover vulnerabilities in your applications and infrastructure before attackers do.

Scan Now