CVE-2022-38371
Published: Oct 11, 2022
Modified: May 13, 2025
CVSS v3.1
7.5
Description
A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions < V3.5.7), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.21), APOGEE PXC Modular (BACnet) (All versions < V3.5.7), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.21), Desigo PXC00-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC00-U (All versions >= V2.3 < V6.30.37), Desigo PXC001-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC100-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC12-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC128-U (All versions >= V2.3 < V6.30.37), Desigo PXC200-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC22.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC36.1-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC50-E.D (All versions >= V2.3 < V6.30.37), Desigo PXC64-U (All versions >= V2.3 < V6.30.37), Desigo PXM20-E (All versions >= V2.3 < V6.30.37), Nucleus NET for Nucleus PLUS V1 (All versions < V5.2a), Nucleus NET for Nucleus PLUS V2 (All versions < V5.4), Nucleus ReadyStart V3 V2012 (All versions < V2012.08.1), Nucleus ReadyStart V3 V2017 (All versions < V2017.02.4), Nucleus Source Code (All versions including affected FTP server), TALON TC Compact (BACnet) (All versions < V3.5.7), TALON TC Modular (BACnet) (All versions < V3.5.7). The FTP server does not properly release memory resources that were reserved for incomplete connection attempts by FTP clients. This could allow a remote attacker to generate a denial of service condition on devices that incorporate a vulnerable version of the FTP server.
| Vendor | Product | Versions |
|---|---|---|
Siemens | APOGEE MBC (PPC) (BACnet) | affected All versions |
Siemens | APOGEE MBC (PPC) (P2 Ethernet) | affected All versions |
Siemens | APOGEE MEC (PPC) (BACnet) | affected All versions |
Siemens | APOGEE MEC (PPC) (P2 Ethernet) | affected All versions |
Siemens | APOGEE PXC Compact (BACnet) | affected 0 - < V3.5.7 |
Siemens | APOGEE PXC Compact (P2 Ethernet) | affected 0 - < V2.8.21 |
Siemens | APOGEE PXC Modular (BACnet) | affected 0 - < V3.5.7 |
Siemens | APOGEE PXC Modular (P2 Ethernet) | affected 0 - < V2.8.21 |
Siemens | Desigo PXC00-E.D | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC00-U | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC001-E.D | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC100-E.D | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC12-E.D | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC128-U | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC200-E.D | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC22-E.D | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC22.1-E.D | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC36.1-E.D | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC50-E.D | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXC64-U | affected V2.3 - < V6.30.37 |
Siemens | Desigo PXM20-E | affected V2.3 - < V6.30.37 |
Siemens | Nucleus NET for Nucleus PLUS V1 | affected All versions < V5.2a |
Siemens | Nucleus NET for Nucleus PLUS V2 | affected All versions < V5.4 |
Siemens | Nucleus ReadyStart V3 V2012 | affected All versions < V2012.08.1 |
Siemens | Nucleus ReadyStart V3 V2017 | affected All versions < V2017.02.4 |
Siemens | Nucleus Source Code | affected 0 - < * |
Siemens | TALON TC Compact (BACnet) | affected 0 - < V3.5.7 |
Siemens | TALON TC Modular (BACnet) | affected 0 - < V3.5.7 |
Weaknesses (CWE)
CVSS v3.1 Details
CVSS v3.1 Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability
Security Training
Train your team to recognize and prevent security threats with our comprehensive security awareness program.
Start TrainingVulnerability Scanning
Discover vulnerabilities in your applications and infrastructure before attackers do.
Scan Now