CVE Database
/

CVE-2023-35796

Back to search

CVE-2023-35796

Published: Oct 10, 2023

Modified: Sep 19, 2024

PUBLISHED

CVSS v3.1

8.3

HIGH

Description

A vulnerability has been identified in SINEMA Server V14 (All versions). The affected application improperly sanitizes certain SNMP configuration data retrieved from monitored devices. An attacker with access to a monitored device could perform a stored cross-site scripting (XSS) attack that may lead to arbitrary code execution with `SYSTEM` privileges on the application server. (ZDI-CAN-19823)

VendorProductVersions

Siemens

SINEMA Server V14

affected
All versions

Weaknesses (CWE)

CVSS v3.1 Details

CVSS v3.1 Vector

CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:C/C:H/I:H/A:H/E:P/RL:U/RC:C

Attack Vector

Network

Attack Complexity

High

Privileges Required

None

User Interaction

Required

Scope

Changed

Confidentiality

High

Integrity

High

Availability

High