Description

A vulnerability has been identified in Security Configuration Tool (SCT) (All versions), SIMATIC Automation Tool (All versions < V5.0 SP2), SIMATIC BATCH V9.1 (All versions < V9.1 SP2 Upd5), SIMATIC NET PC Software V16 (All versions < V16 Update 8), SIMATIC NET PC Software V17 (All versions), SIMATIC NET PC Software V18 (All versions < V18 SP1), SIMATIC NET PC Software V19 (All versions < V19 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC05), SIMATIC PDM V9.2 (All versions < V9.2 SP2 Upd3), SIMATIC Route Control V9.1 (All versions < V9.1 SP2 Upd3), SIMATIC S7-PCT (All versions < V3.5 SP3 Update 6), SIMATIC STEP 7 V5 (All versions < V5.7 SP3), SIMATIC WinCC OA V3.17 (All versions), SIMATIC WinCC OA V3.18 (All versions < V3.18 P025), SIMATIC WinCC OA V3.19 (All versions < V3.19 P010), SIMATIC WinCC Runtime Advanced (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 6), SIMATIC WinCC Runtime Professional V17 (All versions < V17 Update 8), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 4), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 2), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 17), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5), SINAMICS Startdrive (All versions < V19 SP1), SINEC NMS (All versions < V3.0), SINEC NMS (All versions < V3.0 SP1), SINUMERIK ONE virtual (All versions < V6.23), SINUMERIK PLC Programming Tool (All versions < V3.3.12), TIA Portal Cloud Connector (All versions < V2.0), Totally Integrated Automation Portal (TIA Portal) V15.1 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 8), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 4), Totally Integrated Automation Portal (TIA Portal) V19 (All versions < V19 Update 2). The affected applications contain an out of bounds read vulnerability. This could allow an attacker to cause a Blue Screen of Death (BSOD) crash of the underlying Windows kernel.

VendorProductVersions

Siemens

Security Configuration Tool (SCT)

affected
0 - < *

Siemens

SIMATIC Automation Tool

affected
0 - < V5.0 SP2

Siemens

SIMATIC BATCH V9.1

affected
0 - < V9.1 SP2 Upd5

Siemens

SIMATIC NET PC Software V16

affected
0 - < V16 Update 8

Siemens

SIMATIC NET PC Software V17

affected
0 - < *

Siemens

SIMATIC NET PC Software V18

affected
0 - < V18 SP1

Siemens

SIMATIC NET PC Software V19

affected
0 - < V19 Update 2

Siemens

SIMATIC PCS 7 V9.1

affected
0 - < V9.1 SP2 UC05

Siemens

SIMATIC PDM V9.2

affected
0 - < V9.2 SP2 Upd3

Siemens

SIMATIC Route Control V9.1

affected
0 - < V9.1 SP2 Upd3

Siemens

SIMATIC S7-PCT

affected
0 - < V3.5 SP3 Update 6

Siemens

SIMATIC STEP 7 V5

affected
0 - < V5.7 SP3

Siemens

SIMATIC WinCC OA V3.17

affected
0 - < *

Siemens

SIMATIC WinCC OA V3.18

affected
0 - < V3.18 P025

Siemens

SIMATIC WinCC OA V3.19

affected
0 - < V3.19 P010

Siemens

SIMATIC WinCC Runtime Advanced

affected
0 - < V17 Update 8

Siemens

SIMATIC WinCC Runtime Professional V16

affected
0 - < V16 Update 6

Siemens

SIMATIC WinCC Runtime Professional V17

affected
0 - < V17 Update 8

Siemens

SIMATIC WinCC Runtime Professional V18

affected
0 - < V18 Update 4

Siemens

SIMATIC WinCC Runtime Professional V19

affected
0 - < V19 Update 2

Siemens

SIMATIC WinCC V7.4

affected
0 - < *

Siemens

SIMATIC WinCC V7.5

affected
0 - < V7.5 SP2 Update 17

Siemens

SIMATIC WinCC V8.0

affected
0 - < V8.0 Update 5

Siemens

SINAMICS Startdrive

affected
0 - < V19 SP1

Siemens

SINEC NMS

affected
0 - < V3.0

Siemens

SINEC NMS

affected
0 - < V3.0 SP1

Siemens

SINUMERIK ONE virtual

affected
0 - < V6.23

Siemens

SINUMERIK PLC Programming Tool

affected
0 - < V3.3.12

Siemens

TIA Portal Cloud Connector

affected
0 - < V2.0

Siemens

Totally Integrated Automation Portal (TIA Portal) V15.1

affected
0 - < *

Siemens

Totally Integrated Automation Portal (TIA Portal) V16

affected
0 - < *

Siemens

Totally Integrated Automation Portal (TIA Portal) V17

affected
0 - < V17 Update 8

Siemens

Totally Integrated Automation Portal (TIA Portal) V18

affected
0 - < V18 Update 4

Siemens

Totally Integrated Automation Portal (TIA Portal) V19

affected
0 - < V19 Update 2

Weaknesses (CWE)

CVSS v3.1 Details

CVSS v3.1 Vector

CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:N/I:N/A:H/E:P/RL:O/RC:C

Attack Vector

Local

Attack Complexity

Low

Privileges Required

Low

User Interaction

None

Scope

Changed

Confidentiality

None

Integrity

None

Availability

High