CVE Database
/

CVE-2024-22039

Back to search

CVE-2024-22039

Published: Mar 12, 2024

Modified: Dec 16, 2025

PUBLISHED

CVSS v3.1

10.0

CRITICAL

Description

A vulnerability has been identified in Cerberus PRO EN Engineering Tool (All versions < IP8), Cerberus PRO EN Fire Panel FC72x IP6 (All versions < IP6 SR3), Cerberus PRO EN Fire Panel FC72x IP7 (All versions < IP7 SR5), Cerberus PRO EN X200 Cloud Distribution IP7 (All versions < V3.0.6602), Cerberus PRO EN X200 Cloud Distribution IP8 (All versions < V4.0.5016), Cerberus PRO EN X300 Cloud Distribution IP7 (All versions < V3.2.6601), Cerberus PRO EN X300 Cloud Distribution IP8 (All versions < V4.2.5015), Cerberus PRO UL Compact Panel FC922/924 (All versions < MP4), Cerberus PRO UL Engineering Tool (All versions < MP4), Cerberus PRO UL X300 Cloud Distribution (All versions < V4.3.0001), Desigo Fire Safety UL Compact Panel FC2025/2050 (All versions < MP4), Desigo Fire Safety UL Engineering Tool (All versions < MP4), Desigo Fire Safety UL X300 Cloud Distribution (All versions < V4.3.0001), Sinteso FS20 EN Engineering Tool (All versions < MP8), Sinteso FS20 EN Fire Panel FC20 MP6 (All versions < MP6 SR3), Sinteso FS20 EN Fire Panel FC20 MP7 (All versions < MP7 SR5), Sinteso FS20 EN X200 Cloud Distribution MP7 (All versions < V3.0.6602), Sinteso FS20 EN X200 Cloud Distribution MP8 (All versions < V4.0.5016), Sinteso FS20 EN X300 Cloud Distribution MP7 (All versions < V3.2.6601), Sinteso FS20 EN X300 Cloud Distribution MP8 (All versions < V4.2.5015), Sinteso Mobile (All versions < V3.0.0). The network communication library in affected systems does not validate the length of certain X.509 certificate attributes which might result in a stack-based buffer overflow. This could allow an unauthenticated remote attacker to execute code on the underlying operating system with root privileges.

VendorProductVersions

Siemens

Cerberus PRO EN Engineering Tool

affected
0 - < IP8

Siemens

Cerberus PRO EN Fire Panel FC72x IP6

affected
0 - < IP6 SR3

Siemens

Cerberus PRO EN Fire Panel FC72x IP7

affected
0 - < IP7 SR5

Siemens

Cerberus PRO EN X200 Cloud Distribution IP7

affected
0 - < V3.0.6602

Siemens

Cerberus PRO EN X200 Cloud Distribution IP8

affected
0 - < V4.0.5016

Siemens

Cerberus PRO EN X300 Cloud Distribution IP7

affected
0 - < V3.2.6601

Siemens

Cerberus PRO EN X300 Cloud Distribution IP8

affected
0 - < V4.2.5015

Siemens

Cerberus PRO UL Compact Panel FC922/924

affected
0 - < MP4

Siemens

Cerberus PRO UL Engineering Tool

affected
0 - < MP4

Siemens

Cerberus PRO UL X300 Cloud Distribution

affected
0 - < V4.3.0001

Siemens

Desigo Fire Safety UL Compact Panel FC2025/2050

affected
0 - < MP4

Siemens

Desigo Fire Safety UL Engineering Tool

affected
0 - < MP4

Siemens

Desigo Fire Safety UL X300 Cloud Distribution

affected
0 - < V4.3.0001

Siemens

Sinteso FS20 EN Engineering Tool

affected
0 - < MP8

Siemens

Sinteso FS20 EN Fire Panel FC20 MP6

affected
0 - < MP6 SR3

Siemens

Sinteso FS20 EN Fire Panel FC20 MP7

affected
0 - < MP7 SR5

Siemens

Sinteso FS20 EN X200 Cloud Distribution MP7

affected
0 - < V3.0.6602

Siemens

Sinteso FS20 EN X200 Cloud Distribution MP8

affected
0 - < V4.0.5016

Siemens

Sinteso FS20 EN X300 Cloud Distribution MP7

affected
0 - < V3.2.6601

Siemens

Sinteso FS20 EN X300 Cloud Distribution MP8

affected
0 - < V4.2.5015

Siemens

Sinteso Mobile

affected
0 - < V3.0.0

Weaknesses (CWE)

CVSS v3.1 Details

CVSS v3.1 Vector

CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C

Attack Vector

Network

Attack Complexity

Low

Privileges Required

None

User Interaction

None

Scope

Changed

Confidentiality

High

Integrity

High

Availability

High

Security Training

Train your team to recognize and prevent security threats with our comprehensive security awareness program.

Start Training

Vulnerability Scanning

Discover vulnerabilities in your applications and infrastructure before attackers do.

Scan Now