CVE Database
/

CVE-2025-30033

Back to search

CVE-2025-30033

Published: Aug 12, 2025

Modified: Mar 10, 2026

PUBLISHED

CVSS v3.1

7.8

HIGH

Description

The affected setup component is vulnerable to DLL hijacking. This could allow an attacker to execute arbitrary code when a legitimate user installs an application that uses the affected setup component.

VendorProductVersions

Siemens

Automation License Manager V6.0

affected
0 - < *

Siemens

Automation License Manager V6.2

affected
0 - < V6.2 Upd3

Siemens

CEMAT V10.0

affected
0 - < *

Siemens

CP PtP Param configuring interface

affected
0 - < *

Siemens

Create MyConfig (CMC)

affected
0 - < V6.9

Siemens

Energy Support Library (EnSL)

affected
0 - < *

Siemens

FM Configuration Package

affected
0 - < *

Siemens

Modular PID CTRL Tool

affected
0 - < *

Siemens

MultiFieldbus Configuration Tool (MFCT)

affected
0 - < V1.5.5.0

Siemens

OpenPCS 7 V10.0

affected
0 - < *

Siemens

OpenPCS 7 V9.1

affected
0 - < *

Siemens

Siemens Network Planner (SINETPLAN)

affected
0 - < *

Siemens

SIMATIC Automation Tool

affected
0 - < *

Siemens

SIMATIC Automation Tool SDK Windows

affected
0 - < *

Siemens

SIMATIC BATCH V10.0

affected
0 - < *

Siemens

SIMATIC BATCH V9.1

affected
0 - < *

Siemens

SIMATIC Control Function Library (CFL) V1.x

affected
0 - < *

Siemens

SIMATIC Control Function Library (CFL) V2.x

affected
0 - < *

Siemens

SIMATIC Control Function Library (CFL) V3.x

affected
0 - < V3.1.0.2

Siemens

SIMATIC Control Function Library (CFL) V4.x

affected
0 - < V4.1

Siemens

SIMATIC D7-SYS

affected
0 - < *

Siemens

SIMATIC eaSie Core Package

affected
0 - < *

Siemens

SIMATIC eaSie Document Skills

affected
0 - < *

Siemens

SIMATIC eaSie PCS 7 Skill Package

affected
0 - < *

Siemens

SIMATIC eaSie Workflow Skills

affected
0 - < *

Siemens

SIMATIC Energy Suite V17

affected
0 - < *

Siemens

SIMATIC Energy Suite V18

affected
0 - < *

Siemens

SIMATIC Energy Suite V19

affected
0 - < V19 Update 4

Siemens

SIMATIC Logon V1.6

affected
0 - < *

Siemens

SIMATIC Logon V2.0

affected
0 - < V2.0 Upd3

Siemens

SIMATIC Management Agent

affected
0 - < V9.1 SP1 Upd8

Siemens

SIMATIC Management Console

affected
0 - < V9.1 SP1 Upd8

Siemens

SIMATIC MTP CREATOR V2.x

affected
0 - < V2.1

Siemens

SIMATIC MTP CREATOR V3.x

affected
0 - < *

Siemens

SIMATIC MTP CREATOR V4.x

affected
0 - < V4.1.0.1

Siemens

SIMATIC MTP CREATOR V5.x

affected
0 - < V5.0.0.1

Siemens

SIMATIC MTP Integrator V1.x

affected
0 - < *

Siemens

SIMATIC MTP Integrator V2.x

affected
0 - < *

Siemens

SIMATIC NET PC Software V16

affected
0 - < *

Siemens

SIMATIC NET PC Software V17

affected
0 - < *

Siemens

SIMATIC NET PC Software V18

affected
0 - < *

Siemens

SIMATIC NET PC Software V19

affected
0 - < *

Siemens

SIMATIC NET PC Software V20

affected
0 - < V20.0 Update 1

Siemens

SIMATIC ODK 1500S

affected
0 - < *

Siemens

SIMATIC PCS 7 Advanced Process Faceplates V9.1

affected
0 - < V9.1 SP2 Upd4

Siemens

SIMATIC PCS 7 Advanced Process Functions V2.1

affected
0 - < *

Siemens

SIMATIC PCS 7 Advanced Process Functions V2.2

affected
0 - < *

Siemens

SIMATIC PCS 7 Advanced Process Graphics V10.0

affected
0 - < *

Siemens

SIMATIC PCS 7 Advanced Process Graphics V9.1

affected
0 - < *

Siemens

SIMATIC PCS 7 Advanced Process Library incl. Faceplates V10.0

affected
0 - < *

Siemens

SIMATIC PCS 7 Advanced Process Library V9.1

affected
0 - < V9.1 SP2 Upd6

Siemens

SIMATIC PCS 7 Basis Faceplates V9.1

affected
0 - < V9.1 SP2 Upd2

Siemens

SIMATIC PCS 7 Basis Library V10.0

affected
0 - < V10.0 SP1 Upd2

Siemens

SIMATIC PCS 7 Basis Library V9.1

affected
0 - < V9.1 SP2 Upd8

Siemens

SIMATIC PCS 7 Industry Library V10.0

affected
0 - < *

Siemens

SIMATIC PCS 7 Industry Library V9.0

affected
0 - < *

Siemens

SIMATIC PCS 7 Industry Library V9.1

affected
0 - < *

Siemens

SIMATIC PCS 7 Logic Matrix V10.0

affected
0 - < *

Siemens

SIMATIC PCS 7 Logic Matrix V9.1

affected
0 - < V9.1 Upd8

Siemens

SIMATIC PCS 7 MPC Configurator

affected
0 - < *

Siemens

SIMATIC PCS 7 PowerControl

affected
0 - < *

Siemens

SIMATIC PCS 7 Standard Chemical Library V10.0

affected
0 - < *

Siemens

SIMATIC PCS 7 Standard Chemical Library V9.1

affected
0 - < *

Siemens

SIMATIC PCS 7 TeleControl

affected
0 - < *

Siemens

SIMATIC PCS 7 V10.0

affected
0 - < V10.0 SP1 UC01

Siemens

SIMATIC PCS 7 V9.1

affected
0 - < V9.1 SP1 UC08

Siemens

SIMATIC PCS 7/OPEN OS V9.1

affected
0 - < *

Siemens

SIMATIC PCS neo V5.0

affected
0 - < *

Siemens

SIMATIC PCS neo V6.0

affected
0 - < V6.0 SP1

Siemens

SIMATIC PDM Maintenance Station V5.0

affected
0 - < *

Siemens

SIMATIC PDM V9.2

affected
0 - < *

Siemens

SIMATIC PDM V9.3

affected
0 - < V9.3 SP1 Upd2

Siemens

SIMATIC Process Function Library (PFL) V4.0

affected
0 - < *

Siemens

SIMATIC Process Historian 2020

affected
0 - < *

Siemens

SIMATIC Process Historian 2022

affected
0 - < *

Siemens

SIMATIC Process Historian 2024

affected
0 - < V2024 SP1 Upd2

Siemens

SIMATIC ProSave V17

affected
0 - < V17 Update 9

Siemens

SIMATIC ProSave V18

affected
0 - < *

Siemens

SIMATIC ProSave V19

affected
0 - < V19 Update 4

Siemens

SIMATIC ProSave V20

affected
0 - < *

Siemens

SIMATIC Route Control V10.0

affected
0 - < *

Siemens

SIMATIC Route Control V9.1

affected
0 - < *

Siemens

SIMATIC S7 F Systems V6.3

affected
0 - < *

Siemens

SIMATIC S7 F Systems V6.4

affected
0 - < *

Siemens

SIMATIC S7-1500 Software Controller V2

affected
0 - < *

Siemens

SIMATIC S7-1500 Software Controller V3

affected
0 - < V31.1.5

Siemens

SIMATIC S7-Fail-safe Configuration Tool (S7-FCT)

affected
0 - < V4.0.1

Siemens

SIMATIC S7-PCT

affected
0 - < V3.5 SP4 Update 1

Siemens

SIMATIC S7-PLCSIM Advanced

affected
0 - < V7.0 Update 1

Siemens

SIMATIC S7-PLCSIM V17

affected
0 - < *

Siemens

SIMATIC S7-PLCSIM V18

affected
0 - < *

Siemens

SIMATIC S7-PLCSIM V19

affected
0 - < *

Siemens

SIMATIC S7-PLCSIM V20

affected
0 - < V20 Update 1

Siemens

SIMATIC Safety Matrix

affected
0 - < *

Siemens

SIMATIC STEP 7 CFC V19

affected
0 - < *

Siemens

SIMATIC STEP 7 CFC V20

affected
0 - < *

Siemens

SIMATIC STEP 7 V5.7

affected
0 - < *

Siemens

SIMATIC Target

affected
0 - < V6.0 SP3

Siemens

SIMATIC WinCC flexible ES

affected
0 - < *

Siemens

SIMATIC WinCC Runtime Advanced

affected
0 - < V17 Update 9

Siemens

SIMATIC WinCC Runtime Professional

affected
0 - < V21

Siemens

SIMATIC WinCC Runtime Professional V20

affected
0 - < *

Siemens

SIMATIC WinCC TeleControl

affected
0 - < *

Siemens

SIMATIC WinCC Unified Line Coordination

affected
0 - < V20

Siemens

SIMATIC WinCC Unified PC Runtime V18

affected
0 - < *

Siemens

SIMATIC WinCC Unified PC Runtime V19

affected
0 - < *

Siemens

SIMATIC WinCC Unified PC Runtime V20

affected
0 - < *

Siemens

SIMATIC WinCC Unified Sequence

affected
0 - < V20

Siemens

SIMATIC WinCC V7.5

affected
0 - < V7.5 SP2 Update 20

Siemens

SIMATIC WinCC V8.0

affected
0 - < V8.0 Update 8

Siemens

SIMATIC WinCC V8.1

affected
0 - < V8.1 Update 3

Siemens

SIMATIC WinCC Visualization Architect (SiVArc) V17

affected
0 - < V17 Update 9

Siemens

SIMATIC WinCC Visualization Architect (SiVArc) V18

affected
0 - < *

Siemens

SIMATIC WinCC Visualization Architect (SiVArc) V19

affected
0 - < V19 Update 4

Siemens

SIMATIC WinCC Visualization Architect (SiVArc) V20

affected
0 - < V20 Update 3

Siemens

SIMIT Rapid Tester

affected
0 - < *

Siemens

SIMIT Simulation Platform

affected
0 - < *

Siemens

SINAMICS Startdrive V17

affected
0 - < *

Siemens

SINAMICS Startdrive V18

affected
0 - < *

Siemens

SINAMICS Startdrive V19

affected
0 - < *

Siemens

SINAMICS Startdrive V20

affected
0 - < *

Siemens

SINEC NMS

affected
0 - < V4.0

Siemens

SINEMA Remote Connect Client

affected
0 - < *

Siemens

SITRANS

affected
0 - < *

Siemens

Standard PID CTRL Tool

affected
0 - < *

Siemens

TeleControl Server Basic V3.1

affected
0 - < V3.1.2.2

Siemens

TIA Administrator

affected
0 - < V3.0.6

Siemens

TIA Portal Cloud Connector

affected
0 - < V2.3

Siemens

TIA Portal Test Suite V17

affected
0 - < *

Siemens

TIA Portal Test Suite V18

affected
0 - < *

Siemens

TIA Portal Test Suite V19

affected
0 - < V19 Update 4

Siemens

TIA Portal Test Suite V20

affected
0 - < V20 Update 3

Siemens

TIA Project-Server

affected
0 - < V2.2

Siemens

TIA Project-Server V17

affected
0 - < *

Siemens

Totally Integrated Automation Portal (TIA Portal) V17

affected
0 - < V17 Update 9

Siemens

Totally Integrated Automation Portal (TIA Portal) V18

affected
0 - < *

Siemens

Totally Integrated Automation Portal (TIA Portal) V19

affected
0 - < V19 Update 4

Siemens

Totally Integrated Automation Portal (TIA Portal) V20

affected
0 - < V20 Update 4

Siemens

WinCC Panel Image Setup

affected
0 - < V17 Update 9

Weaknesses (CWE)

CVSS v3.1 Details

CVSS v3.1 Vector

CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Attack Vector

Local

Attack Complexity

Low

Privileges Required

None

User Interaction

Required

Scope

Unchanged

Confidentiality

High

Integrity

High

Availability

High

Security Training

Train your team to recognize and prevent security threats with our comprehensive security awareness program.

Start Training

Vulnerability Scanning

Discover vulnerabilities in your applications and infrastructure before attackers do.

Scan Now
CVE-2025-30033 | HIGH (7.8) - Security Vulnerability | QwikSec