Description

A vulnerability has been identified in RUGGEDCOM RST2428P (6GK6242-6PA00) (All versions < V3.2), SCALANCE XCH328 (6GK5328-4TS01-2EC2) (All versions < V3.2), SCALANCE XCM324 (6GK5324-8TS01-2AC2) (All versions < V3.2), SCALANCE XCM328 (6GK5328-4TS01-2AC2) (All versions < V3.2), SCALANCE XCM332 (6GK5332-0GA01-2AC2) (All versions < V3.2), SCALANCE XRH334 (24 V DC, 8xFO, CC) (6GK5334-2TS01-2ER3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 12xFO) (6GK5334-3TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230 V AC, 8xFO) (6GK5334-2TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-3AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 12xFO) (6GK5334-3TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24 V DC, 8xFO) (6GK5334-2TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-2AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 12xFO) (6GK5334-3TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230 V AC, 8xFO) (6GK5334-2TS01-4AR3) (All versions < V3.2), SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+) (6GK5334-5TS01-4AR3) (All versions < V3.2). The "Load Configuration from Local PC" functionality in the web interface of affected products contains a race condition vulnerability. This could allow an authenticated remote attacker to make the affected product load an attacker controlled configuration instead of the legitimate one. Successful exploitation requires that a legitimate administrator invokes the functionality and the attacker wins the race condition.

VendorProductVersions

Siemens

RUGGEDCOM RST2428P

affected
0 - < V3.2

Siemens

SCALANCE XCH328

affected
0 - < V3.2

Siemens

SCALANCE XCM324

affected
0 - < V3.2

Siemens

SCALANCE XCM328

affected
0 - < V3.2

Siemens

SCALANCE XCM332

affected
0 - < V3.2

Siemens

SCALANCE XRH334 (24 V DC, 8xFO, CC)

affected
0 - < V3.2

Siemens

SCALANCE XRM334 (230 V AC, 12xFO)

affected
0 - < V3.2

Siemens

SCALANCE XRM334 (230 V AC, 8xFO)

affected
0 - < V3.2

Siemens

SCALANCE XRM334 (230V AC, 2x10G, 24xSFP, 8xSFP+)

affected
0 - < V3.2

Siemens

SCALANCE XRM334 (24 V DC, 12xFO)

affected
0 - < V3.2

Siemens

SCALANCE XRM334 (24 V DC, 8xFO)

affected
0 - < V3.2

Siemens

SCALANCE XRM334 (24V DC, 2x10G, 24xSFP, 8xSFP+)

affected
0 - < V3.2

Siemens

SCALANCE XRM334 (2x230 V AC, 12xFO)

affected
0 - < V3.2

Siemens

SCALANCE XRM334 (2x230 V AC, 8xFO)

affected
0 - < V3.2

Siemens

SCALANCE XRM334 (2x230V AC, 2x10G, 24xSFP, 8xSFP+)

affected
0 - < V3.2

Weaknesses (CWE)

CVSS v3.1 Details

CVSS v3.1 Vector

CVSS:3.1/AV:N/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N

Attack Vector

Network

Attack Complexity

High

Privileges Required

Low

User Interaction

Required

Scope

Unchanged

Confidentiality

None

Integrity

High

Availability

None