CVE-2025-40594
Published: Sep 9, 2025
Modified: Mar 10, 2026
CVSS v3.1
6.3
Description
A vulnerability has been identified in SINAMICS G220 V6.4 (All versions < V6.4 HF2), SINAMICS S200 V6.4 (All versions < V6.4 HF7), SINAMICS S210 V6.4 (All versions < V6.4 HF2). The affected devices allow a factory reset to be executed without the required privileges due to improper privilege management as well as manipulation of configuration data because of leaked privileges of previous sessions. This could allow an unauthorized attacker to escalate their privileges.
| Vendor | Product | Versions |
|---|---|---|
Siemens | SINAMICS G220 V6.4 | affected 0 - < V6.4 HF2 |
Siemens | SINAMICS S200 V6.4 | affected 0 - < V6.4 HF7 |
Siemens | SINAMICS S210 V6.4 | affected 0 - < V6.4 HF2 |
Weaknesses (CWE)
CVSS v3.1 Details
CVSS v3.1 Vector
CVSS:3.1/AV:L/AC:H/PR:N/UI:R/S:C/C:N/I:H/A:L
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability
Security Training