CVE-2025-5825
Published: Jun 25, 2025
Modified: Jun 25, 2025
CVSS v3.0
7.5
Description
Autel MaxiCharger AC Wallbox Commercial Firmware Downgrade Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of Autel MaxiCharger AC Wallbox Commercial charging stations. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a firmware image before using it to perform an upgrade. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the device. Was ZDI-CAN-26354.
| Vendor | Product | Versions |
|---|---|---|
Autel | Autel MaxiCharger AC Wallbox Commercial | affected 1.36.00 |
Weaknesses (CWE)
CVSS v3.0 Details
CVSS v3.0 Vector
CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability
References
Security Training