CVE-2025-9818
Published: Sep 17, 2025
Modified: Sep 17, 2025
CVSS v3.1
6.7
Description
A vulnerability (CWE-428) has been identified in the Uninterruptible Power Supply (UPS) management application provided by OMRON SOCIAL SOLUTIONS Co., Ltd., where the executable file paths of Windows services are not enclosed in quotation marks. If the installation folder path of this product contains spaces, there is a possibility that unauthorized files may be executed under the service privileges by using paths containing spaces.
| Vendor | Product | Versions |
|---|---|---|
OMRON SOCIAL SOLUTIONS CO., Ltd. | PowerAttendant Standard Edition | affected 0 - <= 2.0.0 |
OMRON SOCIAL SOLUTIONS CO., Ltd. | PowerAttendant Basic Edition | affected 0 - <= 1.1.0 |
OMRON SOCIAL SOLUTIONS CO., Ltd. | PowerAct Pro <Slave Agent> | affected 0 - <= 5.20 |
OMRON SOCIAL SOLUTIONS CO., Ltd. | PowerAct Pro <Master Agent> | affected 0 - <= 5.17 |
OMRON SOCIAL SOLUTIONS CO., Ltd. | Simple Shutdown Software | affected 0 - <= 2.51 |
Weaknesses (CWE)
CVSS v3.1 Details
CVSS v3.1 Vector
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Attack Vector
Attack Complexity
Privileges Required
User Interaction
Scope
Confidentiality
Integrity
Availability
Security Training